151
Pepperl+Fuchs Group · Tel.: Germany (6 21) 7 76-0 · USA (3 30) 4 25 35 55 · Singapore 7 79 90 91 Internet http://www.pepperl-fuchs.com
Issue date: 17.4.2009
AS-Interface
Appendix: example of a bidirectional safety coupling
18. Appendix: example of a bidirectional safety coupling
The following example describes a biderectional safety coupling between 2 AS-i
circuits.
Couple slave A
Couple slave B
AS-i circuit 1, relais circuit 1
AS-i circuit 1, relais circuit 2
AS-i circuit 2, relais circuit 1
AS-i circuit 1:
relais circuit 1: All EMERGENCY STOPs in circuit 1.
relais circuit 2: Alle other safety objects + couple slave B.
AS-i circuit 2:
relais circuit 1: All EMERGENCY STOPs in circuit 2 + couple slave A