EasyManua.ls Logo

Philips LPC2129 - Realmonitor Build Options

Philips LPC2129
306 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RealMonitor 304 May 03, 2004
Philips Semiconductors Preliminary User Manual
LPC2119/2129/2194/2292/2294ARM-based Microcontroller
REALMONITOR BUILD OPTIONS
RealMonitor was built with the following options:
RM_OPT_DATALOGGING=FALSE
This option enables or disables support for any target-to-host packets sent on a non RealMonitor (third-party) channel.
RM_OPT_STOPSTART=TRUE
This option enables or disables support for all stop and start debugging features.
RM_OPT_SOFTBREAKPOINT=TRUE
This option enables or disables support for software breakpoints.
RM_OPT_HARDBREAKPOINT=TRUE
Enabled for cores with EmbeddedICE-RT. This device uses ARM-7TDMI-S Rev 4 with EmbeddedICE-RT.
RM_OPT_HARDWATCHPOINT=TRUE
Enabled for cores with EmbeddedICE-RT. This device uses ARM-7TDMI-S Rev 4 with EmbeddedICE-RT.
RM_OPT_SEMIHOSTING=FALSE
This option enables or disables support for SWI semi-hosting. Semi-hosting provides code running on an ARM target use of
facilities on a host computer that is running an ARM debugger. Examples of such facilities include the keyboard input, screen
output, and disk I/O.
RM_OPT_SAVE_FIQ_REGISTERS=TRUE
This option determines whether the FIQ-mode registers are saved into the registers block when RealMonitor stops.
RM_OPT_READBYTES=TRUE
RM_OPT_WRITEBYTES=TRUE
RM_OPT_READHALFWORDS=TRUE
RM_OPT_WRITEHALFWORDS=TRUE
RM_OPT_READWORDS=TRUE
RM_OPT_WRITEWORDS=TRUE
Enables/Disables support for 8/16/32 bit read/write.
RM_OPT_EXECUTECODE=FALSE
Enables/Disables support for executing code from "execute code" buffer. The code must be downloaded first.
RM_OPT_GETPC=TRUE
This option enables or disables support for the RealMonitor GetPC packet. Useful in code profiling when real monitor is used in
interrupt mode.
RM_EXECUTECODE_SIZE=NA