Lift Motor Replacement
This procedure provides instruction to replace the Lift Motor.
Specifications
System Component Specification
Lift Motor Jackscrew Calibration
Distance*
1-1/4”
Incline A/D
1
Calibration Level 223
Crossramp Lift Yoke Mounting Bolts 240 in-lbs (20 ft-lbs, 27 Nm)
Lift Motor Mounting Bolts 60 in-lbs (6.8 Nm)
1
analog to digital converter
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.