Clearing the Error Log
The Error Log history is cleared by 1) running the Hardware Validation “Error Log Reset”
systems test and 2) cycling the input power.
1. Go to the Hardware Validation Systems Tests page (Service Access Code
51765761), see Accessing Service Software.
2. Use Up/Down arrow softkeys to select the Error Log Reset > Test.
3. Select Start to reset the Error Log.
4. Cycle the input power (OFF/ON).
5. Go to the Display Error Log page and verify that all error codes have been cleared,
select Settings > Information > Error Log).
6. Select Home to exit and return to the Home page.
Error Code Troubleshooting Guide
There is a set of standard error codes implemented across Precor exercise equipment.
Error codes are system generated error codes designed to detect and report fault con-
ditions. Each error code is associated with a particular system or component fault condition.
The maintenance software monitors error code event conditions, when a fault is detected,
the error code is stored in the Error Log along with the event mileage, hours, and motor cur-
rent.
Error Code Troubleshooting Guide: Error Code Troubleshooting Guide.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 217
7 Troubleshooting
Error Log Display

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Precor Precision 400 Series and is the answer not in the manual?

Precor Precision 400 Series Specifications

General IconGeneral
BrandPrecor
ModelPrecision 400 Series
CategoryTreadmill
LanguageEnglish

Related product manuals