Also each Precor elliptical must be connected to a separate 15 amp individual branch circuit
outlet. That means that no other devices can be connected to the same circuit outlet recept-
acle.
l
Individual branch circuit: An individual branch circuit provides a hot conductor and
neutral conductor to a receptacle. The conductors must not be looped, "daisy-
chained", or connected to any other conductors or receptacles. The circuit must be
grounded according to NEC guidelines or local region electric codes.
CAUTION:All NEC (National Electric Code) guidelines or local region electric
codes must be complied with.
Equipment Spacing Requirement
The minimum side to side spacing between ellipticals is 23.6 in (0.6 m) and the minimum
front to back spacing is 79 in (2 m).
The minimum side to side spacing between elliptical trainers is 23.6 in (0.6 m) and the min-
imum front to back spacing is 23.6 in (0.6 m).
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 17
2 General Information
Equipment Spacing Requirement