6. Verify the Step-up and Drive belt alignment and tracking:
Start a manual workout and pedal at a high speed for 1 minute or more and stop.
Then visually inspect and verify that the step-up and input drive belts remain parallel
to each other and maintain even spacing: Repeat test several times to ensure proper
operation.
a. If the belt alignment and tracking is bad, cannot maintain alignment and track-
ing, then make adjustments as needed. Go to the Belt Alignment and Tracking
procedure.
b. If the belt alignment and tracking is good, no adjustment is necessary.
Belt Tension and Alignment Procedure
Belt Tension Adjustment and Alignment Procedure
1. Switch the machine power “OFF” and unplug the power cord from the wall outlet.
2. Remove the rear drive covers, see "Covers and Panels Replacement" on page75.
3. Remove the left and right stairarms from the crankarms, "Stairarm Assembly Replace-
ment" on page163.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 53
5 Adjustment Procedures
Input Drive and Step-up Belt Tension Adjustment

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Precor Precision 400 Series and is the answer not in the manual?

Precor Precision 400 Series Specifications

General IconGeneral
BrandPrecor
ModelPrecision 400 Series
CategoryTreadmill
LanguageEnglish

Related product manuals