Handling the printer PrismJET 54 Gen2 OPERATION MANUAL
138 4.4 Operating from the operation panel
5. Press the [Enter] key on the operation panel.
• “Warming Up Skip ->E” is displayed on Operation panel.
• While “Warming Up” is displayed, do not touch Platen and Media guide.
They become very hot and you could burn yourself.
• You can start printing during warming up.
4.4.8 Start Printing during Warm up
• A confirmation pattern for Automatic PF adjustment is printed.
(Starts printing after warming up is complete.)
6. The printer scans the print using the embedded color sensor, then automatically performs a PF
adjustment.
• Once successfully completed, the message “Auto Adjust Succeeded” will appear on the panel.
• If failed, the message “Auto Adjust Failed” will appear on the panel.
• In the following cases, perform manual PF adjustment.
4.2.6 Media feed adjustment
• If the print defect persists after automatic PF adjustment.
• If the automatic PF adjustment failed.