13.4 EXCHANGE A DEGRADED BATTERY PACK
After 150 charging cycles it is recommended to exchange the UAV Battery pack. In order to check the amount of charging
cycles please check the BID Info menu on the charger – therefore, the battery must be connected to the charger.
The battery will age over time. Therefore, the warranty of the complete UAV system expires when batteries with more than 150
charging cycles are used. Batteries itself are not covered as part of the standard warranty (see chapter 2.2.4).
Note: The UAV is equipped with a feature to return home if the battery is low.
13.5 INSPECTION SCHEDULE
After every 10th ight of the UAV it is recommended to perform a short maintenance check according to the following steps. In
case the check shows any erratic behaviour please contact your reseller for further assistance.
13.5.1 Battery voltage check
• Please connect the battery to the charger after every 10th ight of each battery.
This check must be done after the ight, before recharging the battery.
• Please check the [Data View] menu and ensure that the 6 single cells are within a range of 0.1 V to each other.
max-min <0.1V: OK
max-min >0.1V: NOT OK
[Data View] [Data View]
Main: 21.30 V Main: 21.29 V
Max: 3.59 V Max: 3.63 V
Min: 3.50 V Min: 3.50 V
3.50 V 3.55 V 3.59 V
3.59 V 3.50 V 3.57 V
3.63 V 3.50 V 3.55 V
3.50 V 3.60 V 3.51 V
13
Inspection & repairs