27
Trinity F90+ user manual
6.1.2 Error messages
ERROR MESSAGES EXPLANATION
[BID Insert / Break] If the battery is disconnected during the charging process, reconnect the battery and press START/ENT on the user
panel. Restart the charging process.
[BID is not Connected] Please do a cross check with another battery to nd out if it is the battery or the charger that is causing the issue.
1. If the battery is causing the issue, please contact your reseller for repair.
2. If the charger is causing the issue, the charger has to be replaced.
[BID Error Data Invalid] Please do a cross check with another battery to nd out if it is the battery or the charger that is causing the issue.
1. If the battery is causing the issue, please contact your reseller for repair.
2. If the charger is causing the issue, the charger has to be replaced.
[Internal temperature] An internal temperature is excessive. Allow the charger to cool down.
[Balance connector Error] Make sure the plug is connected correctly.
[Charging Timeout] Please continue charging/discharging the battery by starting a new charging/discharging cycle. Depending on the state
of charge the warning will be triggered during discharging.
6.2 CHARGING / DISCHARGING THE BATTERY PACK
For charging the Trinity battery pack use the QS Battery Charger only. Before charging please see 2.2.2 for the charging
safety instructions.
6.2.1 Connecting the charger to the battery
Rear panel
1a. Connect the power cord to the AC 100 – 240 V port and connect it to a wall socket.
1b. Alternative: charging the battery with the help of a car battery. Connect the XT 60
power cord to the DC 11 – 18 V port and connect the black clamp to the minus pole
and the red clamp to the plus pole of the car battery.
6
Battery & RC Transmitter