EasyManua.ls Logo

Quantum Trinity F90+ - Flight Setup - Step by Step; Step 1: Weather Suitability Check

Quantum Trinity F90+
168 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
86
Trinity F90+ user manual
After planning the mission in QBase follow the steps below for the ight setup.
The steps 8.1 – 8.12 must be completed in the following order.
8.1 Step 1 – Ensure that the weather conditions are suitable for ying
It is possible to y the UAV under the following conditions:
1. Wind up to 9 m / s (17.5 kn) (See chapter 3.1.)
In addition to wind data provided by QBase or meteorological service check the
actual windspeed using the anemometer.
MODE SET
First time start-up of the anemometer
Switch on the anemometer by pressing and holding MODE for 2 seconds.
Set measuring method to MAX by pressing MODE for 3 seconds till m/s is blinking.
Press SET until MAX is shown blinking. Press MODE to conrm.
To reset the MAX-value press MODE for 3 seconds till m/s is blinking.
Then press MODE to conrm.
For more details see the brief manual delivered with the anemometer.
2. Temperature -12 °C to 50 °C (10.4 °F to 122 °F)
Below 0 °C (32 °F): non icing conditions, battery must be heated to 25 °C (77 °F) for at least ve hours before the ight
and the ight time is limited to 60 minutes. Do not y in rain or snow.