QubicaAMF XLi EDGE Pinspotter
Section 4.5 Page 4.5-12 Rev. Date: 10/2016
4.5.23 Service the Distributor Assembly
Refer to the XLi EDGE Distributor Manual for information relating to this maintenance activity.
4.5.24 Service the Table Drive
1. Run the Sweep to the 1
st
Guard position.
2. Run the Table to the pin spotting height.
3. Remove power from the pinspotter. Follow the appropriate Lock out/Tag out procedures.
4. Manually crank the Table up a couple of inches, slide a 2x4 under it in the center, then crank the
Table down so that it rests on the 2x4. The Table must be supported to allow the bolt to be
removed from the Clevis.
5. Remove the nut and bolt securing the Clevis to the Table Torque Tube. Set the bearing and
spacers aside. Try to keep the Clevis from turning on the rod end to prevent having to adjust the
Table height during reassembly.
6. Loosen the nut and bolt clamping the Table Drive Assembly to the Table Drive Shaft.
7. Remove the Table Drive Assembly from the Table Drive Shaft. Be careful of the key.
8. Remove the Clevis Rod End from the Table Eccentric Drive.
9. Check the Clevis for wear. Replace as needed.
10. Check the Clevis Rod End Bearings for excessive play or binding. Replace as needed.
11. Remove the Latch Arm Assembly, Link Actuator Assembly, and Latch Assembly by removing their
corresponding roll pins and shafts from the Table Drive Housing.
12. Check the bushings in the Table Drive Housing and the Latch Assembly Sleeve for excessive play.
Replace as needed.
13. Check all of the actuating mechanism for loose or worn parts. Replace as needed.
14. Remove the locking nut from the bolt that is securing the Table Drive Eccentric to the Table Drive
Housing.
15. Remove the Table Drive Eccentric from the housing.
16. Clean all the grease from the roller bearings.
17. Check that the roller bearings rotate freely. If not replace.
18. Apply a liberal amount of new grease to the roller bearings and inside the housing.