QubicaAMF XLi EDGE Pinspotter
Section 4-6 Page 4.6-34 Rev. Date: 10/2016
4.6.6.3 PROBLEM: Front end motor will not run.
Figure 4.6-33
NO
Replace defective part.
YES
Binding in
motor, gearbox,
or linkage?
NO
Repair or replace
motor.
YES
Motor turns
with hand
crank?
NO
Replace switch.
YES
YES
YES
YES
START
Chassis AC
breaker off?
Turn breaker on.
NO
Motor Power cable
disconnected?
Reconnect cable.
NO
Thermal overload
switch tripped?
Reset switch after
cooling-off period.
Switch will
not reset?
Switch
resets, but
trips again?
YES
Defective
brake?
Replace brake.
YES
NO