Messages and Error Codes
SM 6-45 M126/M127/M128
Trouble-
shooting
Error code Description Action
802
Too many timeouts occurred during
ECM reception.
If error persists disable ECM
mode.
803 Fax cancelled by user No action needed.
804
Unexpectedly received a disconnect
command from the remote end.
Check line quality.
Adjust Transmit
Level/Receive Threshold
values.
Remote device could be
requesting an unsupported
feature.
805
Remote fax device failed to respond
to the DCS command.
Adjust Transmit
Level/Receive Threshold
values.
Remote device could be
malfunctioning.
808
T1 timeout occurred when trying to
establish a connection with a remote
fax device.
Adjust Transmit
Level/Receive Threshold
values.
809
T2 Timeout occurred due to loss of
command/response
synchronization.
Adjust Transmit
Level/Receive Threshold
values.
80A
T5 Timeout occurred when
transmitting image data to remote
fax device.
Check line quality.
Adjust ‘Transmit Level’.
Select a lower ‘Max
Speed ’value under Fax Send
settings.
80B
Too many errors when transmitting
in ECM mode.
Check line quality.
Adjust ‘Transmit Level’.
Select a lower ‘Max Speed’
value under Fax Send
settings.