Loading...
This should only be used as a reference value, because the power consumption specifications are
measured in a controlled environment with a constant power supply.
To get an exact measurement at the customers site, a watt meter must be used to measure the actual
energy consumed.
To use SP8941 to calculate the energy consumed:
At the start of the measurement period, read the values of SP8941 001 to 005.
At the end of the measurement period, read the values of SP8941 001 to 005 again.
Find the amount of time spent in each mode (subtract the earlier measurement from the later
measurement).
Multiply this by the power consumption spec for each mode.
Convert the result to kWh (kilowatt hours)
Here is an example calculation.
Machine
Condition
SP8941:
Machine
Status
Time at
Start (min.)
Time at End
(min.)
Running
time
(hour)
( - )/
60 =
Power
consumption
Spec. (W)
Power
consumption
(KWH)
( x )/1000
=
Operating 001:
Operatin
g Time 21089.0 21386.0 5.0 1081.8 5.35
Stand by
(Ready)
002:
Standby
Time 306163.0 308046.0 31.4 214.0 6.72
Energy save
(Panel off)
003:
Energy
Save
Time 71386.0 75111.0 62.1 214.0 13.29
Low power
004: Low
Power
Time 154084.0 156340.0 37.6 146.0 5.49
Off/Sleep
005: Off
Mode
Time 508776.0 520377.0 193.4 7.0 1.35
Total 32.20
Energy Save