No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
165 D
Copy Data Security Unit error
• The copy data security board is not detected when the copy data security
function is set "ON" with the initial setting.
•
A device check error occurs when the copy data security function is set "ON"
with the initial setting.
•
Incorrect installation of the copy data security board
• Defective copy data security board
1. Reinstall the copy data security board.
2. Replace the copy data security board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
195 D
Serial Number Mismatch
• Serial number stored in the memory does not have the correct code.
• NVRAM defective
• BCU replaced without original NVRAM
1.
Check the serial number with SP5-811-002.
2. If the stored serial number is incorrect, contact your supervisor.
SC 2xx: Exposure
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
202 D
Polygon motor error 1: ON timeout
The polygon mirror motor did not reach the targeted operating speed within 10
sec. after turning on or changing speed
203 D
Polygon motor error 1: OFF timeout
The polygon mirror motor did not leave READY status within 3 sec. after polygon
motor switched off.
3. Appendix: Service Call Conditions