No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
144 D
SBU communication error
Connection to the SBU could not be confirmed, possibly due to a defect in the
BCU detection port.
Harness connection at IPU, BCU, SBU loose, broken, defective
Spurious electrical noise on power supply line
IPU defective
BCU defective
SBU defective
1. Replace the harness.
2. Replace the IPU.
3.
Replace the SBU.
4. Replace the BCU.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
161 D IPU error
001 D
The error result of self-diagnostic by the ASIC on the BCU is detected.
Defective BCU
Defective connection between BCU and SBU
1.
Check the connection between BCU and SBU.
2. Replace the BCU.
002
D
The machine detects an error during an access to the Ri.
Defective BCU board
Replace the BCU board.