Loading...
4603
AGC Execution
Executes the AGC.
1 HP Detection Enable
2 HP Detection Disable
4604
FGATE Open/Close
Opens or closes the FGATE signal. This SP automatically returns to the default status
(close) after exiting this SP.
[0 or 1 / 0 / 1 / step]
0: OFF, 1: ON
Note:
When the registration sensor goes ON, the BCU generates the FGATE signal and
sends it to the LD units.
As soon as the LD units receive the FGATE signal, they send a feedback signal to
the BCU.
SC230, SC231 if the FGATE signal fails to switch on or off.
4609*
Gray Balance Set: R
Adjusts the gray balance of the red signal for each scanning mode.
1 Book Scan
[-384 to 255 / -46 / 1 digit ]
2 DF Scan
4610
Gray Balance Set: G
Adjusts the gray balance of the green signal for each scanning mode.
1 Book Scan
[-384 to 255 / -20 / 1 digit ]
2 DF Scan
4611*
Gray Balance Set: B
Adjusts the gray balance of the blue signal for each scanning mode.