2
Last Correct Value: BO
Color
Displays the previous black offset value for the odd blue
signal in the CCD circuit board.
[0 to 16383 / 0 / 1 digit/step]
4658*
Analog Gain Adjust Last Correct Value: R Color
Displays the previous gain value of the amplifiers on the controller for Red.
[0 to 7 / 0 / 1 digit/step]
4659*
Analog Gain Adjust Last Correct Value: G Color
Displays the previous gain value of the amplifiers on the controller for Green.
[0 to 7 / 0 / 1 digit/step]
4660*
Analog Gain Adjust Last Correct Value: B Color
Displays the previous gain value of the amplifiers on the controller for Blue.
[0 to 7 / 0 / 1 digit/step]
4661*
Digital Gain Adjust
RE: Red Even signal, RO: Red Odd signal
1
Last Correct Value: RE
Color
Displays the previous 2nd black offset value for the even
red signal in the CCD circuit board.
[0 to 1023 / 0 / 1 digit/step]
2
Last Correct Value: RO
Color
Displays the previous 2nd black offset value for the odd
red signal in the CCD circuit board.
[0 to 1023 / 0 / 1 digit/step]
4662*
Digital Gain Adjust
GE: Green Even signal, GO: Green Odd signal
1
Last Correct Value: GE
Color
Displays the previous 2nd black offset value for the even
green signal in the CCD circuit board.
[0 to 1023 / 0 / 1 digit/step]