7. Phase A →B : indicates the phase deviation between the threshold middle
values on the rising edge of Source A and falling edge of Source B. The phase
formula is as follows:
°360×=
sourceA
FR
FR
Period
BDelayA
BPhaseA
Wherein,
FR
BPhaseA
represents Phase A →B ,
FR
BDelayA
represents Delay A
→B , and
represents period of Source A.
8. Phase A
→B : indicates the phase deviation between the threshold middle
values on the falling edge of Source A and the rising edge of Source B. The phase
formula is as follows:
°360×=
sourceA
RF
RF
Period
BDelayA
BPhaseA
Wherein,
RF
BPhaseA
represents Phase A →B ,
RF
BDelayA
represents Delay A
→B , and
represents period of Source A.
NOTE
Source A and Source B can be any channel among CH1-CH4, Math1-Math4, and D0-D15.
You can press > Add to enter the sub-menu to set the parameters.
The default threshold middle value is 50%. You can press > Setting to enter the
sub-menu to set the parameters.