Rockwell Automation Publication 2071-UM001E-EN-P - November 2013 119
Maintain and Troubleshoot Your Kinetix 3 Servo Drive Chapter 9
Emergency Stop
Emergency stop (E-STOP) signal detected. Remove Emergency stop conditions.
Clear E-STOP.
Index Position Range
Overflow
The value of a Position Parameter for
indexing is out of the range.
Use a value within the range of
-2
31
…+2
31
.
Motor Phase Over Current
Anomaly with control or main power
circuitry if this error occurs when power
is turned on.
Excessive current to the motor if this
error occurs during operation (current
more than 300% of the rated current to
the motor more than 10 ms).
Check wiring and power.
Check power and set/adjust acceleration/
decceleration time.
Axis Not Homed
A user tries any indexing without Homing
operation completed.
Complete homing before indexing
Table 35 - Error Displays (continued)
Error
Code
Text
Message
Possible Cause Action/Solution

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation Allen-Bradley Kinetix 3 2071-AP8 and is the answer not in the manual?

Rockwell Automation Allen-Bradley Kinetix 3 2071-AP8 Specifications

General IconGeneral
BrandRockwell Automation
ModelAllen-Bradley Kinetix 3 2071-AP8
CategoryServo Drives
LanguageEnglish

Related product manuals