15.2 Examples of electrical connections
Connection to one heating element
U
1
PRIM.
U
2
SEK.
UPT
®
U
1
PRIM.
U
2
SEK.
UPT
®
1
2
3
Illustration34: Component wiring, example 1
Example 1
Connect the measurement cable (1) directly to the heating element.
Background information: To prevent measurement errors caused by unintention-
ally measuring the line resistances, do not connect to the pulse transformer (3).
Lay the lines going in opposite directions close together.
U
1
PRIM.
U
2
SEK.
U
1
PRIM.
U
2
SEK.
UPT
®
UPT
®
11
2
Illustration35: Component wiring, example 2
Example 2
When objects have to be circumvented, especially iron or steel parts such as I-
beams(1), lay the lines going in opposite directions on the same side whenever
possible.
Laying measuring cable (2) as twisted pair.
U
1
PRIM.
U
2
SEK.
U
1
PRIM.
U
2
SEK.
UPT
®
UPT
®
3
12
Illustration36: Component wiring, example 3