8 | Functions and settings
Page 60 of 104 CIRUS
®
UPT-6400 VERSION 1 | EN-US
Analog output
Various information can be output at the analog output (terminals17+18). The temper-
ature controller is configured in the Machine menu, menu number406.
The following functions can be adjusted:
Setting Description
Actual temperature (default) The analog output indicates the current actual
value at output voltage of0...10VDC.
In the event of an alarm, this analog output is used
– in addition to the indication on the screen – ito
output differentiated error messages.
10V reference A fixed reference of 10VDC is output at the actual
value output.
Regulation ratio The analog output supplies the current regulation
ratio of the temperature controller. The
range0...10VDC show0…100% of the phase-
angle control of the line voltage.
OFF The analog output is deactivated.
8.3.4 Outputs relay K1, relay K2 and outputA1
There are various functions that can be configured for the outputs relay K1, relay K2
and outputA1.
Specifying functions
The function of relayK1 is specified in the Machine menu, menu number407.
The function of relayK2 is specified in the Machine menu, menu number408.
The function of OUTPUTA1 is specified in the Machine menu, menu number409.
With relaysK1 andK2, switching on means closing the Normally-Open contacts (NO)
and opening the Normally-Closed contacts (NC).
OutputA1 is a semiconductor output (open collector). In this case, switchon means
that the transistor is conductive.
37
38
T
emperature controller
50 mA
GND
+24 VDC
GND
I
max
Illustration16: Output A1, terminals 37+38
The following functions can be set for the outputs:
Setting Description
OFF The output remains off.
ON The output remains on.