8 | Functions and settings
Page 78 of 104 CIRUS
®
UPT-6400 VERSION 1 | EN-US
2. Press Up and Down to select ON.
3. Press Enter.
Usable recipe
Which recipes can be used is specified in the Operation menu, menu number213.
Which recipes can be e.g. tested and enabled is specified in this menu.
To set the recipes that can be used, proceed as follows:
1. Move to the Operation menu, menu number213 (Usable recipe).
2. Press Enter to select a recipe.
3. Use Up and Down to select the checkmark to confirm or the X to deselect.
4. Press Enter.
Tip
Use the configuration block to protect the values in the Configuration menu from
being changed unintentionally; refer to section Blocking configuration menu [}78].
This prevents any more recipes from being saved. Usable recipes can no longer be
configured.
Using recipe mode in conjunction with the configuration block allows only enabled
recipes to be used in the temperature controller.
Active recipe
The standard screen shows the recipe number of the recipe that is currently active.
This is done by comparing the currently set values to the content of the recipes. If a
recipe corresponds to the currently active settings, its recipe number is displayed. If no
recipe corresponds to the currently active settings, a line appears.
Tip
Recipes are easy to process with the aid of the visualization software ROPEXvisual
®
.
The following functions can be performed in the visualization software ROPEXvisual
®
.
• Change recipe names
• Change recipes
• Load recipes
• Compare recipes
Section USB interface explains how to download the visualization software ROPEXvi-
sual
®
.
8.7.2 Blocking configuration menu
The ability to change values and parameters can be blocked in the Configuration
menu. This prevents unpermitted changes to the temperature controller configuration.
Proceed as follows to to block or unblock:
1. Switch off the temperature controller.
2. Press and hold down the Menu button.
3. Switch on the temperature controller.
4. Hold down the Menu button until the switchon message is no longer visible.
ð The message "Configuration menu BLOCKED" or "Configuration menu NOT
BLOCKED" appears in the display for three secs.
ð Then the standard screen appears.
1
2
If the Configuration menu is blocked, the individual menu numbers or menu items
are displayed. Values cannot be entered or changed. In the Configuration menu,
an open(1) or closed(2) lock symbol indicates whether or not values can be changed.
Default
The default setting of the Configuration menu is that it is not blocked.