Maintenance | 11
VERSION 1 | EN-US CIRUS
®
UPT-6400 Page 89 of 104
11 Maintenance
NOTICE
Dust deposits can impair proper functioning.
Dust can hinder proper functioning of the temperature controller.
When it is de-energized, dust can be removed from the temperature controller with
dry compressed air.
Install a temperature controller in the electrical cabinet or terminal box for protection
class IP54 or higher.
NOTICE
Contamination with liquids can impair proper functioning
Contamination with liquids can hinder proper functioning of the temperature controller.
Install a temperature controller in the electrical cabinet or terminal box for protection
class IP54 or higher.
The temperature controller requires no special maintenance.
Regular inspection and/or tightening of the terminals including the terminals for the
winding connections on the pulse transformer is recommended.