4 | Description of project
Page 18 of 104 CIRUS
®
UPT-6400 VERSION 1 | EN-US
Install unfiltered and filtered lines in separate wiring ducts.
Follow the instructions in the line filter operating instructions.
Comply with the application report.
4.5.6 Measurement cable
Use a twisted measurement cable supplied by ROPEX (UML-1 or UML-2). Connect
the measurement cable directly to the clamping head on the sealing bar.
The measurement cables UML-1 and UML-2 are twisted cables used for voltage mea-
surement in conjunction with RESISTRON
®
and CIRUS
®
temperature controllers.
Further information can be found on the measurement cable data sheet.
4.6 Optional system components
4.6.1 Booster
If the continuous current is greater than 5A or the pulsed current is greater than 25A,
use abooster; refer to section How to order. Refer to the application report for more
detailed information.