Technical data | 13
VERSION 1 | EN-US CIRUS
®
UPT-6400 Page 93 of 104
Element Technical data
Protection class Protection class I
Degree of contamina-
tion
PD2
Certification CSA, file number 304066
Assembly
• Installation in cut-out of the control panel (width: 138
(±0.2)
mm×height: 68
(±0.2)
mm)
• Secure with fixing hooks
Weight (including plug-
in terminal parts)
0.8kg
Housing material Black plastic, type Noryl SE1 GFN2
Front: Polycarbonate, Lexan 923A transparent 110V0
Back panel: Polycarbonate, Lexan 503R black 739
Connecting cable termi-
nal 1…4
(type/cross-section)
• Screw connection with tension bushing
• Rigid or flexible; 0.2…4 mm² (AWG 24…10) plug-in terminals
• Insulation length: 7 mm
• Torque: 0,5…0,6Nm (screwdriver: SZS 0.6×3.5mm)
Note: If ferrules are used, they must be crimped in accordance with DIN 46228 and
IEC / EN 60947-1. This is essential to ensure proper electrical contact in the termi-
nals.
Connecting cable termi-
nal 5…40
(type/cross-section)
• Push-in spring clamp
• Rigid or flexible; 0.2…2.5 mm² (AWG 24…12) plug-in terminals
• Insulation length: 10 mm
Note: If ferrules are used, they must be crimped in accordance with DIN 46228 and
IEC / EN 60947-1. This is essential to ensure proper electrical contact in the termi-
nals.
13.2 Modification
Owing to its universal design, the temperature controller is suitable for a wide range of
heat-sealing applications.
There are device modifications available for special applications (MOD).
The modifications must be ordered separately.
Modification Function Use
MOD01 Additional booster for low sec-
ondary voltage
(U
R
= 0.2…60VAC).
Essential e.g. when using very
short or low-resistance heating el-
ements.
13.3 How to order
Illustration Device Article number
Temperature controller UPT-6400 7640040
Modification MOD… (optional)
Example: MOD01 additional booster for low volt-
age
10)
800001
10
Example:
To order a temperature controller with additional booster for low voltage: UPT-6400 + MOD01
The order is then: Art. no. 7640040 + 800001.