Functions and settings | 8
VERSION 1 | EN-US CIRUS
®
UPT-6400 Page 81 of 104
Illustration32: TCR calculator
1
Setpoint or temperature measured
by the temperature controller
2
Currently set temperature coeffi-
cient
3
Newly calculated temperature coef-
ficients for calculation of the tem-
perature
Note: Apply the newly calculated
temperature coefficient only if it is
plausible.
4
Newly calculated temperature coef-
ficient (TCR) (based on externally
measured temperature and cur-
rently set temperature coefficient)
5
Current temperature of the heating
element measured with an external
thermometer (or externally mea-
sured temperature entered by the
user)
More information on the TCR calculator can be found in the download area on the
ROPEX website:
www.ropex-group.com/downloads
8.9 Adapting to special sealing applications
8.9.1 Measuring pulse duration
The length of the measuring pulses generated by the temperature controller can be
set with this parameter.
It may be necessary to set a measuring pulse longer than the default 1.7ms for cer-
tain applications. Refer to the application report for more detailed information, or con-
sult support: https://www.ropex-group.com/contact-support/.