Functions and settings | 8
VERSION 1 | EN-US CIRUS
®
UPT-6400 Page 67 of 104
Setting Description
Start heating In the standard screen, pressing Manual triggers
manual heating. Heating continues for as long as
Manual is pressed.
Start sealing cycle In the standard screen, pressing Manual triggers
a sealing cycle (incl. cooling, when applicable).
Key disabled In the standard screen, Manual is disabled,
meaning it has no function. This prevents Manual
from being pressed and heating to begin uninten-
tionally.
8.5.2 Setting temperature unit
Select the unit to be used for temperature display and input in the Operation menu,
menu number204.
The following temperature units are available:
Celsius (°C)
Fahrenheit (°F)
The temperature unit can be changed while the temperature controller is operating.
If the temperature unit Fahrenheit was selected, the temperature controller still contin-
ues to work with Celsius internally. Converting from Celsius to Fahrenheit can cause
the values shown in the temperature display and input to jump around accordingly,
meaning that they might not precise.
8.5.3 Hold mode
Set the behavior of the digital display of the actual temperature in the standard screen
in the Operation menu, menu number203. Proceed as follows:
Setting Meaning
Off (default) The current actual temperature is shown in realtime.
On The current actual temperature is output at the end of the last heat-
sealing phase.
When the temperature controller is switched on, the current tempera-
ture is indicated up until the end of the first heating phase.
2 sec The current temperature is shown as a digital value for an additional
2sec at the end of a heat-sealing phase.
Then the actual temperature is shown in realtime until the end of the
next heat-sealing phase.
Hold mode applies only to the digital value shown in the screen. For all of the settings,
the progress bar and the actual value output always show the actual temperature in
realtime.
The various hold modes are shown below: