8 | Functions and settings
Page 50 of 104 CIRUS
®
UPT-6400 VERSION 1 | EN-US
Menu Menu number Menu item Setting
Setting 105 Cooling tempera-
ture / cooling time
Absolute cooling
temperature: 50°C
Relative cooling
temperature: 40%
cooling time:
1.00sec
107 AUTOCAL tempera-
ture
20°C
110 Correction factor 100%
111 Counter 0
112 Load recipe
115 Temperature of re-
lease pulse
0°C
116 Release pulse delay 0.00sec
117 Duration of release
pulse
0.00sec
Configuration 201 Language German
202 Default
203 Hold mode OFF
204 Temperature unit Celsius
205 AUTOCAL button Active
206 MANUAL button Starts heating
207 Record measured
values
Heating phase
208 Return time 30sec
209 Screen saver OFF
212 Save recipe
213 Usable recipe All can be used
214 Recipe mode OFF
Heating element 301 Temperature coeffi-
cient
1700 ppm/K
302 Temperature coeffi-
cient
1700 ppm/K
303 Source of the TCR
calculator tempera-
ture
Internal
304 TCR calculator,
measured tempera-
ture
300°C (value not
saved)
305 Temperature range Max. 300°C
306 Maximum tempera-
ture
300°C
307 Measuring pulse du-
ration
17 (1.7ms)
311 Calibration channel 0