Specifications and Reference Data
March 2017
Reference Manual
00809-0100-4108, Rev CA
Specifications and Reference Data
84
CS Custom alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet) ★
CT Rosemount standard low alarm ★
Pressure testing
P1 Hydrostatic testing with certificate
Cleaning process area(11)
P2 Cleaning for special service
P3 Cleaning for <1 PPM Chlorine/Fluorine
Ground screw
(12)
V5 External ground screw assembly ★
Surface finish
Q16 Surface finish certification for sanitary remote seals ★
Toolkit total system performance reports
QZ Remote seal system performance calculation report ★
Conduit electrical connector
GE M12, 4-pin, male connector (eurofast) ★
GM A size mini, 4-pin, male connector (minifast) ★
NACE certificate
(13)
Q15 Certificate of compliance to NACE MR0175/ISO15156 for wetted materials ★
Q25 Certificate of compliance to NACE MR0103 for wetted materials ★
316 SST tagging
Y2 316 SST Nameplates, labels, tags, and fasteners ★
Typical model number: 3051P G 3 A 2B 2 1 A B4
1. Rosemount 3051PG lower range limit varies with atmospheric pressure.
2. Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field configured to HART
Revision 5 or 7 if desired. HART Revision 5 is the default HART output.
3. Materials of Construction comply with recommendations per NACE
®
MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain
materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
4. Only available with product certifications I1 or no approvals.
5. “Assemble-to” items are specified separately and require a completed model number.
6. Panel mounting bolts are not supplied.
7. Not available with Alloy C-276 isolator (option code 3), Assemble-to manifolds (option code S5), assemble-to seals (option code S1), surface finish certification (option
code Q16), and remote seal system report (option code QZ).
8. Contact an Emerson Automation Solutions representative for availability.
9. Select Configuration buttons (option code D4 or DZ) or LOI (option code M4) if local configuration buttons are required.
10. Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
11. Not valid with alternate process connection S5.
12. The V5 option is not needed with T1 option; external ground screw assembly is included with the T1 option.
13. NACE compliant wetted materials are identified by <HotXRef_Table_Footnote>Footnote 3.
Figure A-6. Rosemount 3051P In-Line Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to
additional delivery lead time.