3. Use the Write Command to change the register value
DIO M0:\> W C_TCP_DHCP_TIMEOUT 10
4. The confirmation of the change will be displayed as (the value 10 is in seconds to receive the IP address
from the Network. This can be adjusted accordingly):
01621 'C_TCP_DHCP_TIMEOUT' char = 0 to 10
5. The RIO will require reboot to establish a connection to the Network. Either remove power or type
REBOOT command and ‘Y’:
M0:\> REBOOT
Execute 'REBOOT'? [Y/N]
Rebooting...
6. Confirmation can be tested by the checking “IPCONFIG” command:
DIO M0:\> IPCONFIG
Ethernet State: Running
IP ADDRESS = 134.32.38.245
IP MASK = 255.255.255.192
IP GATEWAY = 134.32.38.193
IP PRI DNS = 192.23.23.192
IP SEC DNS = 192.23.23.193
MAC ADDR = 00:50:C2:BE:3F:EF
HOST NAME = UNSPECIFIED_ID
DHCP: On