EasyManua.ls Logo

SEW-Eurodrive MOVISAFE DCS B Series

SEW-Eurodrive MOVISAFE DCS B Series
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56
Manual – MOVIDRIVE® MDX61B Safety Module MOVISAFE® DCS..B Option
5
Connecting binary outputs
Installation
The DCS..B option has separate signal processing paths for every safety output (DO0
DO2).
Example:
Signal processing in two channels and double output in the DCS..B option (PES).
2411078411
PES = Programmable electronic system
I
A
= Input channel A
I
B
= Input channel B
L
A
= Logic channel A
L
B
= Logic channel B
O
A
= Output channel A
O
B
= Output channel B
c = Cross comparison
m = Monitoring
2411107595
PES = Programmable electronic system
I
A
= Input channel A
I
B
= Input channel B
L
A
= Logic channel A
L
B
= Logic channel B
O
A
= Output channel A
O
B
= Output channel B
c = Cross comparison
m = Monitoring
K1 = Actuator 1
K2 = Actuator 2
Binary output Output voltage Output current
DO0_P
DO0_M
DC 24 V
DC 0 V
0.1 A
DO1_P
DO1_M
DC 24 V
DC 0 V
DO2_P
DO2_M
DC 24 V
DC 0 V
1.5 A
Actuator
I
A
O
A
L
A
I
B
O
B
L
B
c
PES
m
m
Actuator
I
A
O
A
L
A
I
B
O
B
L
B
c
PES
m
m
K1
K2

Table of Contents

Related product manuals