Product Description
FLOWSIC100 Flare · Operating Instructions · 8013344/11L2/V 2-5/2018-10 · © SICK Engineering GmbH 35
Subject to change without notice
2.2.1.1 Type code for sender/receiver units ATEX Zone 1, IECEX and Zone 2
The sender/receiver units are defined by a type code as follows:
Parameter Code Design/Description Type of sender/receiver unit
FLSE100
identification
EXS Transducer with small dimensions
EX Transducer with medium dimensions
EXRE
Transducer with medium dimensions,
retractable version of sender/receiver unit
EXPR
Transducer with small dimensions, probe
version
NL
(
→
pg. 31, Fig. 5)
148 148 mm FLSE100-EXS, non-retractable
1
1
Flange connection prepared for mounting on counter flange 2" CL150 RF acc. to ASME B16.5
176 176 mm FLSE100-EXS, non-retractable
2
2
Flange connection prepared for mounting on counter flange DN50 PN16 form B1 acc. to EN 1092-1
198 198 mm FLSE100-EX, non-retractable
1
220 220 mm FLSE100-EXPR, non-retractable, short version
3
3
Flange connection prepared for mounting on counter flange 3" CL150 RF acc. to ASME B16.5 or counter flange DN80 PN16 form B1 acc. to EN
1092-1
226 226 mm FLSE100-EX, non-retractable
2
330 330 mm FLSE100-EXS, retractable
4
4
Flange connection prepared for mounting on counter flange 2" CL150 RF acc. to ASME B16.5 or counter flange DN50 PN16 form B1 acc. to EN
1092-1
350 350 mm FLSE100-EXPR, non-retractable, long version
3
380 380 mm FLSE100-EXRE, retractable
4
400 400 mm FLSE100-EXPR, retractable, short version
3
530 530 mm FLSE100-EXPR, retractable, long version
3
Material of transducer
with probe tube
S
Stainless steel 1.4571, 1.4404,
316L, 316 Ti
not for FLSE100-EXPR
T Titanium
A Hastelloy
F Full titanium execution
Connection flange
A2 see footnote
1
FLSE100-EXS/EX/EXRED5 see footnote
2
A3 see footnote
5
5
Flange connection prepared for mounting on counter flange 3" CL150 RF acc. to ASME B16.5
FLSE100-EXPRD8 see footnote
6
6
Flange connection prepared for mounting on counter flange DN80 PN16 form B1 acc. to EN1092-1
Probe design
1 High flow center path
2 High flow outer path (secant)
Transducer
4 42 kHz preferably FLSE100-EX and EXRE
8 80 kHz preferably FLSE100-EXS
1 135 kHz preferably FLSE100-EXS and EXPR
Sealing material in
retraction mechanism
V FKM
E EPDM
K FFKM
P PTFE