Installation of Expansion and Option Module
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual
4-23
For internal distribution only Installation
● On the HiPath 1190/1190R
Installation Procedures
Step Procedure
1. Turn off the power supply.
2. Remove the system’s front cover.
3. Remove the system’s back cover.
4. Move the module’s latch as shown in Figure 4-14.
5. Insert the module into one of the slots shown in Table 4-3.
6. Move the module’s latch back to secure module.
7. Connect the Main Distribution Frame cables as follows: For modules allo-
cated to the system’s bottom slots (slots 1 to 10) use the bottom opening
(see Figure 4-12). For modules allocated to the system’s top slots (slots
11 to 20) route the cables through the top anchors (see Figure 4-13).
8. Connect to the appropriate module connectors (see “Expansion Module
(EB)” on page 3-16).
9. Attach cables to anchors using plastic brackets.
10. “Performing a Visual Inspection” on page 4-48.
11. Reassemble the entire set.
12. Turn on the power supply.
13. Configure the required data (see “Operation” on page 6-1).