Entrance Telephone Interface
Modules For internal distribution only
A31003-K1250-S100-12-7619
3-50 HiPath 1100, Service Manual
Interfaces
Model: S30817-K930-A300 - TFE
Without amplifier, for installation of the following models:
EGUCOM (Ackermann, Emmerich)
Grothe,Telegärtner
HDL - Brazil (models: F3A, F4A, F5A)
Follow the diagram on Figure 3-34 for installing HDL models for Brazil.
Additional components include: R1 (1.2 k / 0.25W / 5%) and R2 (33 / 0.25W / 5%)
resistors, and C1 capacitor (1.0 µ F / 250 Vac / Non-polarized). The connection to the
PABX is made with two wires (a1 / b1) while the connection to the Entrance Tele-
phone interface is made with four wires (a2 / b2, KL1, KL2).
Model: S30122-k7696-F313 - TFE
With amplifier, for installation of the following models
Telekom Doorline M202
Siedle
Ritto
Figure 3-34 TFE Interface Overview - S30817-K930-A300
For more information, see the TFE Adapter Installation Manual A31003-E8000-X167-
*-19 included with the TFE interface.