EasyManua.ls Logo

Siemens HiPath 1130 - Technical Data

Siemens HiPath 1130
251 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Dat
a
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual
2-7
For internal distribution only System Data
Table 2-3 shows the slots and their Highways.
2.6 Technical Data
Table 2-3 Distribution of modules on the HiPath 1190 backplanes
Slot 11 12 13 14 15 16 17 18 19 20
Highways
2 X
5 X X X
6 X X X
7 X X X
Slot 01 02 03 04 05 06 07 08 09 10
Highways
1 X X
2 X X
3 X X X
4 X X X
Table 2-4 Technical Data
Element HiPath 1120 HiPath 1130 HiPath 1150 HiPath 1190
Dimensions for a Standard Enclosure
Length 14.17" (360 mm) 18.50" (470 mm) 16.53" (420 mm)
Depth 11.33" (288 mm) 14.56" (370 mm) 15.51" (394 mm)
Height 2.53" (64.4 mm) 2.83" (72
mm)
3.93" (100
mm)
19.60" (498 mm)
Weight 2.64 lb (1.2 kg) 8.04 lb (3.65
kg)
9.36 lb (4.25
kg)
49.60 lb (22.5 kg)
Electrical Specifications for the Power Supply Units (PSUs)
Power Require-
ments (Input)
220V / 127mA
127V / 331mA
110V / 381mA
110 - 230V, Full range / 1.5A
Operation Fre-
quency
50/60Hz 50/60Hz
Rated Voltage
(Output)
U1: 8 V
rms
U2: 23 V
rms
5.1 V
DC
.
26.4 V
DC
.