EasyManua.ls Logo

Siemens HiPath 1130 - Option Modules (MO); S0 Module

Siemens HiPath 1130
251 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Option Modules (MO
)
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual
3-25
For internal distribution only Modules
3.6 Option Modules (MO)
3.6.1 S
0 Module
Introduction
This module provides access to ISDN networks and network resources through 2/5
S
0
standard digital access channels (10 or 4).
Functions
Each ISDN access enables two communications channels. The ISDN line may
also be used for video conferencing (external connection, outside the exchange).
Depending on your carrier, some features may be provided, including Caller ID,
Caller ID Blocking, Direct Dialing to Extensions and so on.
HiPath 1120
Interfaces
The Figure 3-12 features a 2-Port S
0
module; also available as a single-Port option.
X3 connector used for EB 800.
Figure 3-12 S
0
HiPath 1120Module
Ta b l e 3 - 1 5 S
0
module connectors HiPath 1120
Port 1
X2 and X3
Port 2
X4 and X5
Slot 1 and 2 - without RT (Resistive Termination)
(factory default)
Slot 3 and 2 - with RT (Resistive Termination)