Installation of Expansion and Option Modules
Installation For internal distribution only
A31003-K1250-S100-12-7619
4-26 HiPath 1100, Service Manual
Installation Diagram
On the HiPath 1190/1190R
Installation Procedures
8. “Performing a Visual Inspectionon page 4-48.
9. Turn on the power supply.
10. Configure the required data (see “Operation” on page 6-1).
Figure 4-21 Installing a Fax/DID Module HiPath 1130/1150
Step Procedure
1. Turn off the power supply.
2. Remove the system’s front cover.
3. Disconnect the Main Distribution Frames cables from the CPU.
4. Move the modules latch as shown in Figure 4-14.
5. Remove the CPU.
6. Attach the separator provided with the Fax/DID module to the CPU.
7. Attach the module to the CPU’s pin connector and the separator.
Step Procedure