Installation of Expansion and Option Modules
Installation For internal distribution only
A31003-K1250-S100-12-7619
4-24 HiPath 1100, Service Manual
4.6.3 Installing a S0 Module
4.6.4 Installing a TME1 Module
4.6.5 Installing an ADSL Module
Installation Procedures
4.6.6 Installing a Fax/DID Module
On the HiPath 1120
Installation Procedures
Warning
For proper system synchronization make sure to connect S
0
interfaces sequentially.
For example, for a 5-interface module with only 2 S
0
lines NT1 must be connected
to the first interface and NT2 to the second interface. The clock reference is only pro-
vided by the S
0
modules first interface.
Warning
Remember to set the DIP switches (see“TME1 Module” on page 3-27).
Step Procedure
1. Connect the carriers ADSL line to slot 1 and 2 of the X2 connector (voice
output).
In the CND version, connect the carrier’s ADSL line to slot 1 of the X2 con-
nector.
2. Connect slots 3 and 4 of the X2 connector to the external line input for
the HiPath 1100. 99 slots
In the CND version, connect to slot 2 of the X2 connector.
3. Connect your network cables to the HUB (J3, J5, J6 and J7 connectors).
Step Procedure
1. Turn off the power supply.
2. Remove the system’s cover
3. Attach the separator provided with the module to the MB.
4. Attach the module to the MB’s pin connector and to the separator.
5. Reassemble the entire set.
!
!