Limitations to System Expansio
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual
2-5
For internal distribution only System Data
2.5 Limitations to System Expansion
Table 2-1 Specific limitations to system expansion
HiPath 1120 HiPath 1130 HiPath 1150 HiPath 1190
Standard Configuration:
External Analog Lines 2 0
Analog Extensions 8 10 0
System Telephone Interface
*
* Each system telephone that is connected occupies one analog telephone slot.
4 88
Expansion Modules
**
:
** If the maximum capacity of an analog external line is exceeded due to the installation of an EB or TME1 module, the system
disables a corresponding number of analog external lines, according to each system’s capacity. The extension slots, how-
ever, will continue to operate as usual.
EB 010 (10 extensions) 0 1414
EB 012 (12 extensions) 0 3 8
EB 202 (2 ext. lines and 2 extensions) 0 2 4 20
EB 204 (2 ext. lines and 4 extensions) 2 0 0
EB 206 (2 ext. lines and 6 extensions) 0 1 4 16
EB 210 (2 external lines and 10 exten-
sions)
0 1 4 8
EB 200 (2 external lines) 2 2 4 16
EB 400 (4 external lines) 0 2 3 8
EB 800 (8 external lines) 0 1 4
Option Modules:
***
***S
0
and TME1 modules cannot be used simultaneously.
An ADSL module and a TME1 module cannot be used simultanously on the HiPath 1150/1190.
S
0 Module
1 2
TME1 Module 0 1 2
ADSL Module 1 1
Fax/DID Module 1 1
CD Module 0 1
Music Module 1 On Board
TFE Entrance Telephone Interface 4
Total System Capacity:
External lines/extensions/system
telephones
6/16/4
17/20/8
12/20/8
10/50/8 or 16/40/8
or 17/46/8
32/140/24 or
45/140/24
External analog lines without TME1 or
S
0
modules
****
**** When using digital trunks, you can determine the maximum number of analog lines by subtracting the number of lines as-
signed to each module from the total line capacity for the systems.
6 14 16 32