TME1 Serial Cabl
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual
3-55
For internal distribution only Modules
3.13 TME1 Serial Cable
The TME1 serial cable (C39195-A9700-B532-*) is used for connecting to a PC or mo-
dem in order to program the system using the HiPath 1100 E1 Trunk Manager tool.
Figure 3-39 Serial cable connection to TME1
TME1 serial cable signals
Table 3-38 TME1 serial cable signals
Pin Signal
DCD Date Carrier Detect
CTS Clear To Send
DSR Date Send Ready
DTR Date Station Ready
GND Ground
RTS Request To Send
RX Receive Data
TX Transmit Data
RI Ring indicator
9-pin male
Mini DIN connector
9-pin female
SubD connector
RI 9
RTS 8
CTS 7
DTR 6
5 GND
4 DSR
3 RX
2 TX
1 DCD
Length: 9.8 feet (3 meters)
MB
PC
Modem
1
2
3
7
6
9
2 = RX
1 = DCD
3 = TX
4 = DTR
5 = GND
7 = RTS
6 = DSR
8 = CTS
9 = RI
2 = RX
1 = DCD
3 = TX
4 = DTR
5 = GND
7 = RTS
6 = DSR
8 = CTS
9 = RI
2 = RX
1 = DCD
3 = TX
4 = DTR
5 = GND
7 = RTS
6 = DSR
8 = CTS
9 = RI