Loading...
Table of the System’s Programming Code
s
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual
7-13
For internal distribution only Configuring the System Specifically for the Client
Updating the Software
Remote Administration
Table 7-10 Updating the Software
Programmed
Functions
Cod
e
Intermediate Data Data to be
Programmed
Completing
Data Entry
Default
SW Information 001 - Displays the software release and
version number, product name, APS,
and serial number.
Any key to final-
ize entry.
Local SW Update 060 Automatic
Activating a SW
Update
055
- To enable
# - To disable
Automatic # - To disable
Day for SW Update 054 dd (day, from 01 to 31) or Automatic 01
Time for SW Update 058 hh:mm (hh from 00 to 23
and mm from 00 to 59)
Automatic 00:00
External Number for
Updating the Soft-
ware
056 Number (up to 20 digits) # instead of
number
None
Frequency for SW
Update
057 Month (01 to 12) Automatic 01
Uploading the SW
Update
059 hh:mm (hh from 00 to 23
and mm from 00 to 59)
Automatic 00:00
Table 7-11 Remote Administration
Programmed
Functions
Code Intermediate Data Data to be
Programmed
Completing
Data Entry
Default
Service Call *994 Number of Service Center # - To confirm Automatic
Remote Software
Update
*9415 Automatic
Remote Operation
Mode
084 1 - Via ISDN
2 - Via Modem
Automatic 1 - Via ISDN
Remote Administra-
tion Activation
066
- To enable
# - To disable
Automatic # - To disable
External Number
Configuration
067 Slot: 1 to 4 Number (up to 20 digits) # instead of
slot
None
Remote Administra-
tion Password
068 Slot: 1 to 4 00000 to 99999 # instead of
slot
None
Remote MSN 069 Slot: 001 to 140 or
- To delete
Automatic None