Comments about the System’s Programming Code
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual
7-21
For internal distribution only Configuring the System Specifically for the Client
7.1.1 Run quick test
Checking terminals
● Check the display of each terminal (for Time and Date). If there is nothing on the
display, it means that there is a problem with the terminals or cables. Replace
the terminal or inspect cables.
● Check analog terminals.
Checking to see if the systems starts up properly
● Make random internal and external calls.
7.2 Comments about the System’s Programming Codes
7.2.1 Important settings
Dialing Mode on an External Analog Line (19)
The system supports two dialing modes for external and absent lines (for unused ex-
ternal line slots):
● DP - Dial Pulse
● MF - Multifrequency (Tone)
Relay
*
75 1 - Switch
2 - Monoflop
3 - Invert
4 - Music on Hold
5 - External signal
Automatic 1 - Switch
Timer for Deactivat-
ing the Relay
73 000 to 255
(intervals of 0.5 s)
# instead of
number
002 - (1
second)
External Ring for
Activating the Relay
071 Extension Automatic None
* When playing music from an external music source all regulations relating to copyrights for the country in question have to
be followed.
Table 7-20 Relay and sensor on the HiPath 1120
Programmed
Functions
Cod
e
Intermediate Data Data to be
Programmed
Completing
Data Entry
Default