Comments about the System’s Programming Code
s
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual
7-31
For internal distribution only Configuring the System Specifically for the Client
Overflow/Escape Extension (32)
An overflow extension only receives calls when the extension to which it is assigned
as overflow is not available.
Hotline (45)
This function lets you dial automatically a number previously programmed into the
Phonebook as soon as the handset is lifted.
Warmline (62)
It allows you to specify a period of time for activating the Hotline.
Each extension can have a different timeout set for the Warmline, from 0 to 9 sec-
onds.
Executive-Secretary (51)
Assigns multiple extensions (Secretary Telephones) to a main telephone set (Execu-
tive Telephone).
There are 8 groups available with 16 extensions each (all extensions must use system
telephones).
CD Interface Assignment (46)
It allows you to connect a system telephone to any extension slot.
The default setting for this assignment is:
The overflow extension can be accessed through the specified internal number and
cannot be used or programmed as a Fax extension.
Multiple extensions can dial a number programmed in the Phonebook.
Table 7-21 CD Interface Assignment
HiPath 1120 HiPath1130/1150/1190
A1/B1 C1/D1 A1/B1 C1/D1
A2/B2 C2/D2 A2/B2 C2/D2
A3/B3 C3/D3 A3/B3 C3/D3
A4/B4 C4/D4 A4/B4 C4/D4