Technical Data
System Data For internal distribution only
A31003-K1250-S100-12-7619
2-8 HiPath 1100, Service Manual
* Values vary according to the country. The values shown are specifically for Brazil.
** Values depend on the country settings, which are configurable. The values shown are default values for Brazil.
Call Voltage U3:
40 V
rms
/60Hz
65 V
rms
/20Hz (CND)
65 V
rms
/25Hz (SPA)
42 V
rms
/25Hz (RSA)
50 V
AC
+ 97 V
DC
/ 0.13A - 25Hz
42 V
AC
+ 85.8 V
DC
/ 0.13A - 25Hz (RSA)
Dialing Modes for Calls to other Public or Private Exchanges:
MF Transmission Level:
Low Group* -11 dBm
High Group* -9 dBm
Pre-Emphasis 2 dB
Pulse Duration** 90ms min.
Inter-digit Pause** 90ms min.
DP (Dial Pulse):
Pulse/Pause Ra-
tio**
2:1 (approximately 70:30ms = 10 Hz)
Inter-digit Pause** 800ms
Open loop isola-
tion resistance
between a/b or a/
ground or b/
ground
> 10M
Closed loop line
resistance/contin-
uous loop current
Complies with national requirements/standards
Incoming Call De-
tection
> 9V
RMS
Values shown are approximate. When making connections, consider the specific
level of tolerance that applies.
Table 2-4 Technical Data
Element HiPath 1120 HiPath 1130 HiPath 1150 HiPath 1190

Table of Contents