EasyManua.ls Logo

Siemens HiPath 1130 - Page 191

Siemens HiPath 1130
251 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table of the System’s Programming Code
s
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual
7-7
For internal distribution only Configuring the System Specifically for the Client
Minimum Time for
UCD Queue On
Hold Message
033 UCD Subscriber Group (00 to 99) in 5-second cycles # instead of
group
00 (0 seconds)
Hunt Groups (HG) 021 Hunt Group (HG) extension or
- To delete
# instead of
group
None
Hunt Group Selec-
tion (HG)
022 Hunt Group (HG) 1 - Linear
2 - Round-robin
# instead of
group
1- Linear
Override 44 Extension 0 - Without permission
1 - With permission and
beep
# instead of
extension
0
Silent Monitoring 046 Extension - To enable
# - To disable
# instead of
extension
# - To disable
Caller ID for analog
extension (CLIP)
010 Analog extension 0 - No Caller ID
1 - DTMF before ringing
2 - DTMF during ringing
3 - FSK before ringing
4 - FSK during ringing
# instead of
extension
0
Electronic Lock
Password Reset
26 Extension Automatic 00000
Timeout when there
is no answer
30 (01 to 99) in 5-second cycles Automatic 06 (30
seconds)
Dialing Mode 68 Extension Detection:
0 - Automatic
1 - Pulse (DP)
2 - Tone (DTMF)
# instead of
extension
0 - Automatic
Flash Detection
Time
31 Extension 1
- 280 ms
*
2 - 750 ms
3 - 1200ms
# instead of
extension
1- (Country-
specific)
Overflow Extension/
Escape Extension
**
32 1 - No answer
2 - Busy
3 - Wrong number
Extension Automatic Extension 11/
101
Hotline 45 Extension (except 11/110) Phonebook entry
000 to 249 or
- without Hotline
# instead of
extension
- Without
Hotline
Warmline 62 Extension (except 11/110) 0 to 9 seconds # instead of
extension
0 seconds
Executive/Secretary 51 Executive extension (up to 8) Secretary extension (up to
15)
or
- To delete
# instead of
extension
None
Table 7-6 Programming an Extension
Programmed
Functions
Cod
e
Intermediate Data Data to be
Programmed
Completing
Data Entry
Default

Table of Contents

Other manuals for Siemens HiPath 1130

Related product manuals