Table of the System’s Programming Code
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual
7-7
For internal distribution only Configuring the System Specifically for the Client
Minimum Time for
UCD Queue On
Hold Message
033 UCD Subscriber Group (00 to 99) in 5-second cycles # instead of
group
00 (0 seconds)
Hunt Groups (HG) 021 Hunt Group (HG) extension or
∗ - To delete
# instead of
group
None
Hunt Group Selec-
tion (HG)
022 Hunt Group (HG) 1 - Linear
2 - Round-robin
# instead of
group
1- Linear
Override 44 Extension 0 - Without permission
1 - With permission and
beep
# instead of
extension
0
Silent Monitoring 046 Extension ∗ - To enable
# - To disable
# instead of
extension
# - To disable
Caller ID for analog
extension (CLIP)
010 Analog extension 0 - No Caller ID
1 - DTMF before ringing
2 - DTMF during ringing
3 - FSK before ringing
4 - FSK during ringing
# instead of
extension
0
Electronic Lock
Password Reset
26 Extension Automatic 00000
Timeout when there
is no answer
30 (01 to 99) in 5-second cycles Automatic 06 (30
seconds)
Dialing Mode 68 Extension Detection:
0 - Automatic
1 - Pulse (DP)
2 - Tone (DTMF)
# instead of
extension
0 - Automatic
Flash Detection
Time
31 Extension 1
- 280 ms
*
2 - 750 ms
3 - 1200ms
# instead of
extension
1- (Country-
specific)
Overflow Extension/
Escape Extension
**
32 1 - No answer
2 - Busy
3 - Wrong number
Extension Automatic Extension 11/
101
Hotline 45 Extension (except 11/110) Phonebook entry
000 to 249 or
∗ - without Hotline
# instead of
extension
∗ - Without
Hotline
Warmline 62 Extension (except 11/110) 0 to 9 seconds # instead of
extension
0 seconds
Executive/Secretary 51 Executive extension (up to 8) Secretary extension (up to
15)
or
∗ - To delete
# instead of
extension
None
Table 7-6 Programming an Extension
Programmed
Functions
Cod
e
Intermediate Data Data to be
Programmed
Completing
Data Entry
Default