Comments about the System’s Programming Codes
Configuring the System Specifically for the Client For internal distribution only
A31003-K1250-S100-12-7619
7-52 HiPath 1100, Service Manual
Number of Attempts for Activating the Sensor (053)
This setting specifies the number of call attempts (between 1 and 100) for the num-
ber specified in ”Number Dialed by Sensor Activation.” (See also Time be-
tween Attempts for Activating the Sensor
).
An attempt is made after every call that was not answered (busy signal), or when the
"Detect DTMF Code" option (Code 70, Option 3) is enabled and no acknowledgment
is received. When this occurs, the call is disconnected and a new attempt is made.
Relay (75)
This setting specifies the operating mode for the relay:
● “Switch" The relay can only be turned on from an extension by entering the
proper feature code (see Miscellaneous Functions - Relay in the User Manual).
● "Monoflop": The relay is closed for a specified length of time. Alternatively, the
relay can also be opened before the set time by entering the proper feature code
(see Miscellaneous Functions - Relay in the User Manual).
● "Invert": The current state of the Relay is reversed when the feature code for ac-
tivating it is selected at an extension.
● "Music on Hold" The Relay can be used for activating external equipment con-
nected for playing announcements/music.
● "External signal" It is possible to use the Relay to control a second ring for an ex-
tension.
Timer for Deactivating the Relay (73)
Specifies the length of time that the relay must remain closed.
External Ring for Activating the Relay (071)
This setting lets you use the relay to control a second ring signal for a specified ex-
tension.
If the closing time is set to "000," the relay will remain active until it is manually de-
activated.