• MRP: Media redundancy, impulsed with 200ms. Precondition: Ring topology
With MRP, you get an uninterrupted switchover if you set the failure monitoring time to a
value > 200ms.
• MRPD: Media redundancy, bumpless. Precondition: IRT and the ring topology created in the
control
• Diagnostic alarms in accordance with the error classes specied in the PROFIdrive prole.
• Device replacement without removable data storage medium: The replacement converter is
assigned the device name from the IO controller, not from its memory card or from the
programming device.
• Shared Device for converters that support PROFIsafe.
The converter as Ethernet node
1$
4*/".*$4
(%
4*/".*$4
(%
4*/".*$4(
4*/".*$4($
4*/".*$4(9
&UIFSOFU
Figure4-45 The converter as Ethernet node (examples)
Further information on the operation as Ethernet nodes can be found in the Function Manual
"Fieldbuses".
Overview of the manuals (Page465)
Further information on PROFINET
Further information on PROFINET can be found on the Internet:
• PROFINET – the Ethernet standard for automation (http://w3.siemens.com/mcms/
automation/en/industrial-communications/pronet/Pages/Default.aspx)
• PROFINET system description (https://support.industry.siemens.com/cs/ww/en/view/
19292127)
Installing
4.10Connecting the interfaces for the converter control
SINAMICS G120C Converters
110 Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK