Function description
The following free function blocks are available:
Table 8-37 Free function blocks
Logic blocks AND0
AND1
AND2
AND3
OR0
OR1
OR2
OR3
XOR0
XOR1
XOR2
XOR3
NOT0
NOT1
NOT2
NOT3
NOT4
NOT5
Calculation
blocks
Adder Subtractor Multiplier Divider Compara‐
tor
Absolute
value
Polyline
ADD0
ADD1
ADD2
SUB0
SUB1
MUL0
MUL1
DIV0
DIV1
NCM0
NCM1
AVA0
AVA1
PLI0
PLI1
Timer blocks Pulse gen‐
erator
Pulse
shorten‐
ing
ON delay OFF delay Pulse stretching
MFP0
MFP1
MFP2
MFP3
PCL0
PCL1
PDE0
PDE1
PDE2
PDE3
PDF0
PDF1
PDF2
PDF3
PST0
PST1
Memory block RS 󹪞ip-󹪞op D 󹪞ip-󹪞op
RSR0
RSR1
RSR2
DFR0
DFR1
DFR2
Breaker block Analog
switch
Binary switch
NSW0
NSW1
BSW0
BSW1
Control block Limiter Smooth‐
ing
Integrator Di󹪜erentiator
LIM0
LIM1
PT10
PT11
INT0 DIF0
Complex block Limit monitor
LVM0
LVM1
You can only use a function block once. The converter has 3 adders for instance, ADD0,
ADD1, and ADD2. If you have already con󹪝gured 3 adders, then no other adders are
available.
Application description for the free function blocks
Further information is provided on the Internet:
FAQ (http://support.automation.siemens.com/WW/view/en/85168215)
Advanced commissioning
8.14Free function blocks
SINAMICS G120C Converters
250 Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK

Table of Contents

Other manuals for Siemens SINAMICS G120C DP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C DP and is the answer not in the manual?

Siemens SINAMICS G120C DP Specifications

General IconGeneral
Protection RatingIP20
Frequency Range0 to 650 Hz
Control ModesV/f, sensorless vector control
Communication InterfacesPROFIBUS DP
Ambient Temperature-10 to +50 °C (without derating), -10 to +60 °C (with derating)
Overload Capacity150 % rated current for 60 s, 200 % rated current for 3 s
Storage Temperature-40 to +70 °C
Relative Humidity5% to 95% (non-condensing)
Voltage Range200 V to 240 V (±10%), 380 V to 480 V (±10%)
Output Voltage0 V to Supply Voltage