Immunity to voltage drop of semiconductor process equipment
The converters comply with the requirements of standard SEMI F47-0706.
China RoHS
The converters comply with the China-RoHs directive. More information is provided on the
Internet:
China RoHS (https://support.industry.siemens.com/cs/ww/en/view/109738656)
Directive of the European Union on Waste Electrical and Electronic Equipment (WEEE)
The converter complies with the requirements of Directive 2012/19/EU with regard to the
return and recycling of waste electrical and electronic equipment.
Quality systems
Siemens AG employs a Quality Management System that meets the requirements of ISO
9001 and ISO14001.
Certi󹪝cates for download
EC Declaration of Conformity: (https://support.industry.siemens.com/cs/ww/en/view/
61862976)
Certi󹪝cates for the relevant directives, prototype test certi󹪝cates, manufacturers
declarations and test certi󹪝cates for functions relating to functional safety ("Safety
Integrated"): (http://support.automation.siemens.com/WW/view/en/22339653/134200)
Certi󹪝cates for products that were certi󹪝ed by UL: (http://database.ul.com/cgi-bin/XYV/
template/LISEXT/1FRAME/index.html)
Certi󹪝cates for products that were certi󹪝ed by TÜV SÜD: (https://www.tuev-sued.de/
industrie_konsumprodukte/zerti󹪝katsdatenbank)
Standards that are not relevant
China Compulsory Certi󹪝cation
The converters do not fall in the area of validity of the China Compulsory Certi󹪝cation (CCC).
Description
3.6Directives and standards
SINAMICS G120C Converters
Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK 33

Table of Contents

Other manuals for Siemens SINAMICS G120C DP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C DP and is the answer not in the manual?

Siemens SINAMICS G120C DP Specifications

General IconGeneral
Protection RatingIP20
Frequency Range0 to 650 Hz
Control ModesV/f, sensorless vector control
Communication InterfacesPROFIBUS DP
Ambient Temperature-10 to +50 °C (without derating), -10 to +60 °C (with derating)
Overload Capacity150 % rated current for 60 s, 200 % rated current for 3 s
Storage Temperature-40 to +70 °C
Relative Humidity5% to 95% (non-condensing)
Voltage Range200 V to 240 V (±10%), 380 V to 480 V (±10%)
Output Voltage0 V to Supply Voltage